Percutaneous Kyphoplasty Application for T4 Vertebral Fracture Under Computerized Tomography
[ X ]
Tarih
2018
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
AVES
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Percutaneous vertebral augmentation procedures for vertebral fractures are increasingly becoming popular. However, due to difficulties in thoracic vertebra morphology and live fluoroscopic imaging, alternate imaging modalities may be needed. In this case report, T4 kyphoplasty application under serial computed tomography imaging is presented.
Açıklama
Anahtar Kelimeler
Kyphoplasty; thoracic; vertebra; fracture